Seitenansicht 11
10
When the battery is completely discharged the LCD will flash
the 15 minute icon and the ‘RES’ bar until the battery is
returned to a charger.
If the protection electronics detect a low battery voltage
condition (any one
cell reaches roughly 2.5Vdc or
approximately 10V battery voltage), the LCD sidebars will flash
until the battery is returned to a charger. If the battery is not
returned to the charger, after a time the Fuel Gauge will be
turned off and the LCD will go completely blank until the
battery is returned to a charger.
LCD ICON’s Indication Action
- Side Bar blinking
- Any others on normally
Learn Full Discharge,
then Charge
- Side Bar blinking
- Any others lit and blinking
Over Current Remove
Excess Load
- Side Bar lit, but NOT
blinking
- All others off
Under
Voltage
Return to
Charger
- Display blank Under
Voltage
Return to
Charger